PID Detector Sensor 200 ppm Alarm Photoionization Detector TVOC Leak Detection MDQ 10 ppb

Model NO.: 045-012
Sensitivity: High
Certification: RoHS
Customized: Customized
Trademark: Baseline Mocon
Transport Package: Factory Sealed
Specification: 20.4*17.6(+4.78)
Origin: United States
HS Code: 9027100090
PID Detector Sensor 200 ppm Alarm Photoionization Detector TVOC Leak Detection MDQ 10 ppb
Upgrades include

• Minimum detection limits down to 0.5 ppb
• Negligible temperature response
• Minimal humidity response
• Integral shielding
• Reduced dead volume
• Reduced and improved response time
• Lower pricing
Intrinsically safe design and 4P platform make installation in
portable or stationary gas monitors a snap.
 

Features and Benefits
• Intrinsically safe
• Saves time and money in R&D and product design
• 4P cell platform compatible
• Variety of ranges and lamp energies
• Quick start lamp ignition circuit
• Long lamp life
• Input voltage regulation for greater stability
• Easily cleaned and field serviced
• Out of warranty Sensor Exchange Program
 
10.6eV Green Purple Red Yellow Blue
Part Number 045-010 045-011 045-012 045-013 045-014
Range * 10,000 ppm 2,000 ppm 200 ppm 20 ppm 2 ppm
MDQ * 500 ppb 100 ppb 10 ppb 1.5 ppb 0.5 ppb
T90 response Factor ≤ 2 sec (typical) ≤ 2 sec (typical) ≤ 2 sec (typical) ≤ 4 sec (typical) ≤ 4 sec (typical)
*Range and MDQ(Mininum Detectable Quantity) are based on isobutylene.

Applications
• Industrial Hygiene & Safety Monitoring
• Confined Space Entry
• Soil Contamination and Remediation
• Hazmat Sites & Spills
• Low Concentration Leak Detection
• Indoor Air Quality
• EPA Method 21
 

Physical Characteristics All sensors calibrated with Isobutylene

Complete sensing unit includes detector cell, UV lamp, lamp driver, amplifier and sample filter
Weight < 8 gr
Package Type 4P cell dimensional profile
Serviceable Parts lamp, detector cell, filters (2), cap, spacer
Lamp Life Guaranteed 6000 hours - Typical life significantly longer
Onboard Filters Removes liquids / particles
Warranty Period 1st of 18 months from ship date or 12 months from install date

Electrical Characteristics
Supply Voltage 3.2V-5.5V (input voltage regulator included)
Current 24mA - 36mA
Power Consumption 80 mW - 200 mW - Dependent upon supply voltage
Output Signal 0.045V - 2.5V

Operating Conditions
Temperature Range -20o C to 60ºC (-4o F to 104ºF)
Relative Humidity Range 0 to 90% non-condensing
Humidity Response < 1 % @ 90% relative humidity
Humidity Quenching Effect < 15% @ 90% relative humidity
Accuracy ±3% of reading, with constant temperature and pressure

Certifications & Approvals*
piD-TECH eVx is a UL certified component. Intrinsically safe - no external components required.
USA UL 913 (Eighth Edition), For use in Class I, Division 1, Groups A, B, C, D Locations.
Europe ATEX directives: EN 60079-0:2012, A11:2013; EN 60079-11:2012, Ex II 1 G Ex ia IIC Ga T4, Tamb = -20C to +60C
ATEX Certificates: DEMKO 13 ATEX 1304446U Rev.1; CE 0539
Other IECEx Standards:60079-0 Ed.6; 60079-11, Ed6; Certificate IECEx UL 13.0050U Issue:1; CAN/CSA C22.2 No. 157-92
Patents US Pat 6,646,444, Japan Pat 3,793,757
*Detailed documentation for specific certification is available upon request. Above certifications are issued for piD-TECH eVx sensor only and are not applicable to the equipment in which it is incorporated.

Mechanical Specifications
PID Detector Sensor 200 ppm Alarm Photoionization Detector TVOC Leak Detection MDQ 10 ppb
 

Stage Monitor Speaker